Citicel 4oxv O2 Sensor Oxygen Gas Detector for Medical & Industrial Safety

Still deciding? Get samples of $ !
Order Sample

Product Description

Technical Specifications
Model NO.
4oxv
Use
Gas Detect
Specification
0-25% vol
Trademark
CITY
Response Time
T90 < 10 seconds
Output Signal
0.10±0.03mA
Storage Life
6 Months in Original Packaging
Humidity Range
5 to 95%Rh
Storage Temp
0°C to 20°C
Weight
15 G
Casing Material
ABS
Origin
United Kingdom
Product Overview
The 4OXV oxygen sensor is a high-performance detection device, suitable for scenarios such as industrial safety, medical care, and environmental monitoring. It can accurately detect oxygen concentrations ranging from 0 to 25% (with a maximum overload of 30%), respond quickly (T90 < 10 seconds), have an annual drift rate of less than 5%, and maintain stable accuracy over long-term use. The sensor can withstand a temperature range of -30 ºC to + 50ºC and a humidity environment of 5-95%RH. The output signal is stable (0.10±0.03mA), and its service life exceeds 2 years. Its anti-interference design is not cross-sensitive to toxic gases within the threshold value, making it suitable for integration requirements in mining, petrochemical, medical equipment, etc.
🛡️ False alarm immunity
⏱️ Reliably meets stated life
🌍 Superior environmental performance
🚀 Enhanced response time in extreme applications
Product Visuals
Packaging & Delivery
Package Size
20.00cm * 15.00cm * 10.00cm
Gross Weight
0.050kg
Transport Package
Cartons
Frequently Asked Questions
What is the detection range of the 4OXV oxygen sensor?
The sensor is designed to detect oxygen concentrations ranging from 0 to 25% vol, with a maximum overload capacity of 30%.
How long does the sensor take to respond to gas changes?
It features an enhanced response time with a T90 rating of less than 10 seconds, making it ideal for safety-critical applications.
What is the expected lifespan and stability of this device?
The 4OXV sensor has a service life exceeding 2 years and maintains high stability with an annual drift rate of less than 5%.
Can it operate in extreme weather conditions?
Yes, it is built for superior environmental performance, operating effectively in temperatures from -30 ºC to +50 ºC and humidity levels between 5-95% RH.
Is the sensor affected by other toxic gases?
The sensor includes an anti-interference design that ensures immunity to false alarms and is not cross-sensitive to common toxic gases within threshold values.
What are the recommended storage conditions?
It is recommended to store the sensor in its original packaging at temperatures between 0°C and 20°C. The shelf life in these conditions is 6 months.

Related Products